Details
-
Bug
-
Status: Closed
-
Major
-
Resolution: Fixed
-
1.2.2
-
None
Description
the repository scanner uses the end time of the previous scan + the duration as the start time for the next scan. This means that any artifacts that are added in that time between scans will not be detected.