Uploaded image for project: 'Flink'
  1. Flink
  2. FLINK-9936

Mesos resource manager unable to connect to master after failover

    XMLWordPrintableJSON

Details

    Description

      When deployed in mesos session cluster mode, the connector monitor keeps reporting unable to connect to mesos after restart. In fact, scheduler driver already connected to mesos master, but when the connected message is lost. This is because leadership is not granted yet and fence id is not set, the rpc service ignores the connected message. So we should connect to mesos master after leadership is granted.

      Attachments

        Issue Links

          Activity

            People

              gjy Gary Yao
              liurenjie1024 Renjie Liu
              Votes:
              0 Vote for this issue
              Watchers:
              5 Start watching this issue

              Dates

                Created:
                Updated:
                Resolved: