UIMA AS not checking state of a Connection when stopping resulting in ConnectionClosedException

    XMLWordPrintableJSON

Details

    • Task
    • Status: Closed
    • Major
    • Resolution: Fixed
    • 2.3.1AS
    • 2.4.0AS
    • Async Scaleout
    • None

    Description

      Jenkins reports an exception when running a new testcase testGenerateAndDeployPrimitiveDD():

      org.apache.activemq.ConnectionClosedException: The connection is already closed
      at org.apache.activemq.ActiveMQConnection.checkClosed(ActiveMQConnection.java:1363)
      at org.apache.activemq.ActiveMQConnection.checkClosedOrFailed(ActiveMQConnection.java:1350)
      at org.apache.activemq.ActiveMQConnection.deleteTempDestination(ActiveMQConnection.java:1933)
      at org.apache.uima.adapter.jms.client.BaseUIMAAsynchronousEngine_impl.stopConnection(BaseUIMAAsynchronousEngine_impl.java:236)
      at org.apache.uima.adapter.jms.client.BaseUIMAAsynchronousEngine_impl.stop(BaseUIMAAsynchronousEngine_impl.java:281)
      at org.apache.uima.adapter.jms.client.BaseUIMAAsynchronousEngineCommon_impl$UimaASShutdownHook.run(BaseUIMAAsynchronousEngineCommon_impl.java:3040)
      at java.lang.Thread.run(Thread.java:595)

      Check the state of a connection while doing cleanup.